SV Serisi - Elkurmalı Solenoid Vanalar, Normalde Açık veya Kapalı
Gastech · SV · SV25 · SV40 · SV50 · SV65 · SV80 · SV100 · SV100C · SV125 · SV150 · SV200 · SV300




SV Serisi Katalog 2024 (EN) SV Serisi Katalog JUN.2024 (EN)
Çizimler
64f893d3af4d3.DWG 64f8946285971.DWG 64f895309ab90.DWG 64f89612174cf.DWG 64f896cbacfec.DWG 64f897cb40231.DWG 64f89d3b21edb.DWG 64f89dccc56d8.DWG 64f89e67bd5ab.DWG 699ec32bc5f0b.DWG 64f893d3af4d3.DWG 64f8946285971.DWG 64f895309ab90.DWG 64f89612174cf.DWG 64f896cbacfec.DWG 64f897cb40231.DWG 64f89d3b21edb.DWG 64f89dccc56d8.DWG 64f89e67bd5ab.DWG 699ec3a2a2c4d.DWG
Elkurmalı Solenoid vanalar, gaz kaçak dedektörleri, yangın kontrol sistemleri vb. sistemlerden gelen sinyaller doğrultusunda gazı kapatır. 2014/68/EU direktiflerine uygun tasarlanmış ve üretilmiştir.
SV Serisi Elle Kurmalı Selenoid Vanalar, Gaz kaçak alarm sistemi, yangın algılama sistemi veya elektrik sinyali üreten herhangi bir kaynaktan gelen sinyaller doğrultusunda gaz akışını kapat için tasarlanmıştır. Gaz borusuna montajlanır ve alarm sistemi ile irtibatlandırılır. Atmosfere açık ve kapalı alanlarda kullanılabilinir. Elektrik sinyali geldiğinde gaz akışı kapanır, tekrar gaz akışını sağlamak için kurma kolunu yukarı kaldırmak gerekir. 2014/68/EU direktiflerine uygun tasarlanmış ve üretilmiştir.
| Teknik Özellikler / Technical Features | ||||
|---|---|---|---|---|
| SV | SV/6b | |||
| Maximum permissible pressure(PS) | 500mbar | 6 bar | ||
| Nominal Size | Threaded Conn. 1/2'' - 3/4'' - 1'' - 11/4'' - 11/2'' - 2'' Flanged Conn. DN 25-32-40-50-65-80-125-150-200-250-300 | |||
| Connections | Threaded series connections: UNI-ISO 7/1 Flanged series connections: ISO 7005 or ANSI Class 150 RF | |||
| Temparature Range | Operatingand ambient temperature -20°C to +70 °C | On request -40 °C | ||
| Materials | Aluminum valve'sbody and cover; stainlesssteel springs and control piston; NBR rubber gasket and O-ring; other part are of brass, aluminum and galvanized steel. | |||
| Working Voltage | 12 Vdc, 12 V/50 Hz, 24 Vdc, 24 V/50 Hz, 110 V/50-60 Hz, 230 V/50-60 Hz | |||
| Power supply voltage tolerance | -15% ... +10% | |||
| Protection degree | IP65 | On request 5μm or 10μm | ||
| Group | 2 | |||
| Optional Explosion Proof Coil | Class «F» coil according to the VDE 0580 regulations. Protection ExII 2G (Eexd IIC T5).Wire insulation Class H (200°C) Electrical insulation IP 67, Certificate of the coil CESI 03 ATEX 212. | |||
| Closing time | < 1 s | |||
| Power Consumption | Threaded11 W, DN65 - DN300 28 W | 612-PED-062/2014-01 | ||
| CE-mark acc. to PED and PIN-Nr. | CE1783 | PED-079 | ||
| Explosion protection | Mechanical components of regulator do not contain a potential ignition source, thus do not fall in limits of ATEX 95 (94/9/EG). (Used electronic accessories comply with ATEX-demands.) | |||
Bu ürün için teknik bilgi ve fiyat teklifi almak isterseniz bize hemen ulaşın: